Short answer: the common standard is one square foot of net free vent area per 150 square feet of attic floor, split roughly half intake at the soffits and half exhaust at the ridge. With a proper vapor retarder, 1 per 300 may apply. Balance matters more than total.

Running the number

Take your attic floor area. Divide by 150. That is your total required net free vent area in square feet. Split it half and half between intake and exhaust.

A 2,000 square foot attic needs roughly 13.3 square feet of net free area total, so about 6.7 at the soffits and 6.7 at the ridge.

Net free area is the actual open area after screening and louvers, not the size of the hole. Vent products publish it, and it is always less than the gross opening.

Balance is the part that matters

Exhaust without intake does not ventilate. If there is more exhaust than intake, the system pulls air from the easiest available source, which is conditioned air leaking up from your house through ceiling gaps. You end up paying to cool air that exits through the ridge.

If anything, intake should slightly exceed exhaust. The opposite is the common defect.

How to check your own attic

Symptoms of a shortfall

Do not mix exhaust types

Ridge vent plus turbines lets one short circuit the other, pulling air in through the turbine rather than from the soffits. Pick one exhaust strategy. Our ventilation comparison covers the options.

Fix it during a replacement

Ventilation correction during a re-roof is inexpensive, because the roof is open and soffits are accessible. Retrofitting later costs several times more for the same result. If you are getting quotes, ask specifically whether intake is being assessed and corrected.